Powergen Engines

 


Stage 1 and 2
Tier 1 and 2
    50 Hz / 1500 rpm   60 Hz / 1800 rpm   Generator
efficiency
(%)
Emission levels
Prime power Standby power Prime power Standby power
Engines   kWm kWe kVA kWm kWe kVA   kWm kWe kVA kWm kWe kVA   EU Stage EPA Tier
TD520GE   75 68 85 83 76 94   77 70 88 85 77 97   91 1 1
TAD530GE   75 68 85 83 76 94   77 70 88 85 77 97   91 2 2
TAD531GE   88 80 100 96 87 109   92 84 105 101 92 115   91 2 2
TAD532GE   113 104 130 124 114 142   115 106 132 127 117 146   92 2 2
TD720GE   113 104 130 124 114 142   115 106 132 127 117 146   92 1 1
TAD730GE   113 104 130 124 114 142   115 106 132 127 117 146   92 2 2
TAD731GE   132 121 152 145 133 167   140 129 161 154 142 177   92 2 2
TAD732GE   162 149 186 179 165 206   179 165 206 197 181 227   92 2 2
TAD733GE   175 161 201 195 179 224   192 177 221 214 197 246   92 2 2
TAD734GE   213 196 245 238 219 274   216 199 248 243 224 279   92 2 2
TAD940GE   241 222 277 265 244 305   248 228 285 273 251 314   92 2 2
TAD941GE   280 260 326 308 286 358   296 275 344 326 303 379   93 2 2
TAD1341GE   271 252 315 298 277 346   287 266 334 317 295 369   93 2 2
TAD1342GE   303 282 352 333 310 387   345 321 401 377 351 438   93 2 2
TAD1343GE   325 302 378 356 331 414   353 328 410 388 361 451   93 2 2
TAD1344GE   354 329 412 389 362 452   392 365 456 431 401 501   93 2 2
TAD1345GE   388 361 451 431 401 501   392 365 456 431 401 501   93 2 2
TAD1640GE   393 369 462 432 406 508   431 405 506 479 450 563   94 2 2
TAD1641GE   430 404 505 473 445 556   485 456 570 546 513 642   94 2 2
TAD1642GE   503 473 591 554 521 651   532 500 625 585 550 687   94 2 2
TWD1643GE   536 504 630 596 560 700   585 550 687 644 605 757   94 2 2
 
Stage 3A
Tier 3
    50 Hz / 1500 rpm   60 Hz / 1800 rpm   Generator
efficiency
(%)
Emission levels
Prime power Standby power Prime power Standby power
Engines   kWm kWe kVA kWm kWe kVA   kWm kWe kVA kWm kWe kVA   EU Stage EPA Tier
TAD550GE   76 69 86 85 77 97   84 76 96 93 85 106   91% 3A 3
TAD551GE   89 81 101 100 91 114   99 90 113 111 101 126   91% 3A 3
TAD750GE   114 105 131 127 115 144   127 117 146 146 134 168   92% 3A 3
TAD751GE   132 121 152 145 133 167   149 137 171 166 153 191   92% 3A 3
TAD752GE   158 145 182 174 160 200   178 164 205 196 180 225   92% 3A 3
TAD753GE   173 159 199 191 176 220   194 178 223 218 201 251   92% 3A 3
TAD754GE   217 200 250 239 220 275   219 201 252 246 226 283   92% 3A 3
TAD1350GE       245 227 284 269 250 313   93% 3A 3
TAD1351GE   274 254 318 301 280 350   294 273 341 323 300 375   93% 3A 3
TAD1352GE   313 291 364 344 320 400   342 318 397 376 350 437   93% 3A 3
TAD1353GE       391 364 454 430 400 500   93% 3A 3
TAD1354GE   327 304 380 360 335 419   342 318 397 376 350 437   93% 3A 3
TAD1355GE   352 327 409 387 360 450   342 318 397 376 350 437   93% 3A 3
TAD1650GE   387 364 455 426 400 501   435 409 512 479 450 563   94% 3A 3
TAD1651GE   425 400 500 468 440 550   484 455 568 532 500 625   94% 3A 3
 
Tier 4i
    60 Hz / 1800 rpm       Generator
efficiency
(%)
Emission levels
  Prime power Standby power    
Engines   kWm kWe kVA kWm kWe kVA       EU Stage EPA Tier
TWD1663GE   593 557 697 655 616 770       94   4i
 
Stage 1 and 2
Tier 1 and 2
400 Hz / 2000 rpm
    400 Hz / 2000 rpm       Generator
efficiency
(%)
Emission levels
  Prime power Standby power    
Engines   kWm kWe kVA kWm kWe kVA       EU Stage EPA Tier
TD720GE   120 110 138 132 121 152       92 1 1
TAD731GE   145 133 166 159 146 183       92 2 2
TAD733GE   171 157 197 192 177 221       92 2 2
 
Net engine performance acc. to ISO3046, BS5514, DIN6271
kWm = kiloWatt mechanical, net with fan
kWe = kiloWatt electrical = kWm x gen. eff.
kVA = kiloVoltAmpere, calculations based on a 0.8 power factor = kWe / 0.8